No.125 CABTYRE CABLE FLEXING TESTER
JIS C3005
- This tester is used to conduct a flexing test on rubber and plastic electric insulated wires.
- The operator is to insert the test specimen into the rotator’s through-hole and attach both ends of the test specimen.
- After the test specimen has been continuously rotated 200 times at a prescript rotating speed, the operator is to check the number of disconnections to each of the wires, cracks, and breakage at the attaching point of piercing point.
Specification
Specifications are subject to change without notice. | |
Roter-Hole Distance | Method A: 100 mm, Method B: 150 mm |
Roter-Chuck Distance | Method A: 300 mm, Method B: 200 mm |
Rotation Speed | 20 rpm |
Counter | 6 Digits Preset Counter |
Power Source | AC 200 V, 1-Phase, 15 A, 50/60 Hz |
Dimensions/ Weight (Approx.) | W1,020 × D820 × H680 mm, 224 kg |
No.254 PLUG FLEXING TESTER
JIS C3662-2, C8306, IEC-60227-2
- This tester is used to test the bending endurance of plugs. Hanging prescript weight on one end of the plug and repeatedly bending the other end 60° back and forth for a prescript number of times.
- After a prescript number of times the plug has been bended, the operator is to check the disconnection rate of the plug to determine the bend stress strength.
- Also, to test chloride insulating cables, the plug will be flexed left and right repeatedly at a 90° angle.
Specification
Specifications are subject to change without notice. | |
Hangings | 1, 2, 3, or 4 Hangings (4 kinds) |
Flexing Angle | Left-Right 60°, 90° (2 Stage Type) |
Flexing Speed | 40 times/min (20 rt/min) |
Weight | 500 g |
Bracing | 300 mm from Pivot, Spacing 40 mm |
Counter | 6 Digits Preset Counter |
Option | Conduction Device |
Power Source | AC 100 V, 1-Phase, 10 A, 50/60 Hz |
Dimensions/ Weight (Approx.) | 1 Hanging : W470 × D505 × H760 mm, 43 kg |
No.256 OUTLET PLUG DURABILITY TESTER
JIS C8306
- This tester is used to conduct an opening and closing test on electric plugs.
- The operator is to evaluate the durability of the plugs by fixing the plug and the outlet to a Chuck and horizontally opening and closing them repeatedly.
- It is also possible to connect a load device to the tester.
Specification
Specifications are subject to change without notice. | |
Hangings | 2, 4, or 6 Hangings (3 kinds) |
In-Out Speed | 10 times/min, 20 times/min (2 Stage Type) |
Counter | 6 Digits Preset Counter |
Option | A-meter, V-meter, Energizing Terminal, Loading Device |
Power Source | AC 100 V, 1-Phase, 5 A, 50/60 Hz |
Dimensions/ Weight (Approx.) | 2 Hangings: W650 × D250 × H450 mm, 50 kg 4 Hangings: W650 × D500 × H600 mm, 60 kg |
No.257 OPTICAL FIBER CABLE FLEXING TESTER
JIS C6821, C6851, C6861, IEC-60794
- This tester is used for conducting flexing tests on optical fiber cables and cords.
- The sample specimen is applied a certain amount of weight and bent 90° in both directions.
- The specimen is then evaluated by examining the damage and loss caused by the test.
Specification
Specifications are subject to change without notice. | |
Hangings | 1 hanging, 3 hangings, 6 hangings (3 kinds) |
Flexing Angle | Left-Right 45°, 60°, 90° (Standard Value 90°) |
Flexing Speed | 2 sec./ 1 cycle |
Flexing Mandrel Diameter | R15 mm |
Weight | 500 g, 1,000 g |
Option | Break Detection Function |
Power Source | AC 100 V, 1-Phase, 10 A, 50/60 Hz |
Dimensions/ Weight (Approx.) | Differs by Specifications. |
No.259 OPTICAL FIBER CRUSH TESTER
JIS C6821, C6851, C6861, IEC-60794
- This tester is for conducting optical fiber cable crushing tests among the testing methods of mechanical characteristics for optical fiber cable or cord.
- The specimen is placed between steel plates and applied force continuously but not rapidly to avoid impact.
- When the test is finished, the specimen is measured the loss and examined after set for 1 min. or more.
Specification
Specifications are subject to change without notice. | |
Movable Plate | Width 100 × Length 200 mm |
Crushing Force | 7 N/mm, 14 N/mm |
Dimensions/ Weight (Approx.) | W700 × 350 × H500 mm, 10 kg |
No.262 ELECTRIC CORD BENDING TESTER
JIS C3662-2, C3663-2, IEC-60227-2, 60245-2
- This tester is to evaluate the flexibility of vinyl chloride and rubber insulation cable.
- The operator is to attach the test specimen at an S-shaped using the 2 pulleys that are fixed on both ends of the machine and also 2 pulleys that are fixed to the slider that slide across the test specimen.
- Test load will be added to both ends, and slide the slider parallel so that tensile force will be added to the opposite direction that the slider is moving to.
- The tester is designed so that it can detect the short circuit during the test.
Specification
Specifications are subject to change without notice. | |
Specimen Sectional Area | 0.5 to 4.0 mm2 |
Pulley | Choose from φ60, 80, 120, 160, 200 mm |
Slider Speed | 0.33 m/sec |
Slider Length | More than 1m |
Weight Load | Choose from Initial 0.5 to 9.0 kg |
Load Device | Electric Current Range: 0.1 to 30 A Per Phase |
Power Source | Primary: AC 200 V, 3-Phase, Star Connect, 20 kVA, 50/60 Hz Secondary: 230 V, 1-Phase/ 400 V (Attached with Voltage Changer), 3-Phase, Star Connection, 3-Phase 4 Line, Neutral Line Earth |
Dimensions/ Weight (Approx.) | W2,240 × D1,000 × H2,050 mm, 950 kg |
Inquiry Form