No.307 MIT TYPE FOLDING ENDURANCE TESTER

- This tester is used to evaluate the folding endurance of paper, cardboard, plastic film, and flexible print circuit boards.
- Applying a certain load and folding the test specimen left and right at a 135°angle at a certain speed, the operator is to count the number of times the test specimen was folded until it fractures.
- The deadweight method is adopted as the loading type for this tester.
- This tester is also used for evaluating the folding endurance of metallic foil such as aluminum foil used in condensers.
Specification
| Specifications are subject to change without notice. | |
| Model | No.307 |
|
Number of Test Stations |
1, 3, or 5 stations |
|
Test Sample |
Width 15.0 ± 0.1 mm, length 110 ± 5 mm |
|
Test Load |
4.9–14.7 N (0.5–1.5 kgf) |
|
Folding Angle |
45˚, 90˚, 135˚ |
|
Folding Rate |
45 double folds/min, 90 double folds/min, 175 double folds/min |
|
Slot of Folding Head |
Radius of curvature 0.38 ± 0.02 mm, length 19.0 ± 0.5 mm, clearance 0.25 mm |
|
Counter |
6-digit preset counter |
|
Options |
Continuity break detector, ohm monitor for dielectric strength measurement, safety cover |
|
Power Source |
AC 100 V or 200 V 1-phase 10–15 A 50/60 Hz |
|
Dimensions and Weight (Approx.) |
1 station: W470×D400×H850 mm, 31 kg |
No.307-L MIT TYPE FOLDING ENDURANCE TESTER (WITH REFRIGERATING MACHINE)

- This model is equipped with a low temp. chamber for testing at low temperatures.
Specification
| Specifications are subject to change without notice. | |
| Model | No.307-L |
|
Number of Test Stations |
3 stations |
|
Test Sample |
Width 15.0 ± 0.1 mm, length 110 ± 5 mm |
|
Test Load |
4.9–14.7 N (0.5–1.5 kgf) |
|
Folding Angle |
45˚, 90˚, 135˚ |
|
Folding Rate |
45 double folds/min, 90 double folds/min, 175 double folds/min |
|
Slot of Folding Head |
Radius of curvature 0.38 ± 0.02 mm, length 19.0 ± 0.5 mm, clearance 0.25 mm |
|
Counter |
6-digit preset counter |
|
Temperature |
-35–60℃ (refrigeration control) |
|
Options |
Continuity break detector, ohm monitor for dielectric strength measurement, safety cover |
|
Power Source |
AC 100 V or 200 V 1-phase 10–15 A 50/60 Hz |
|
Dimensions and Weight (Approx.) |
W950×D830×H1,550 mm, 350 kg |
Inquiry Form
Contact Us For over 70 years, Yasuda Seiki’s testing machines have supported quality control and research & development across various industries, meeting the diverse needs of our clients.