No.105 WILLIAMS PLASTOMETER
JIS K6249, ASTM D926, ISO 7323
- Placing the specimen on the parallel plate and after adding prescribed load for a specific amount of time, the plastometer reads the thickness of the specimen and multiplies the thickness 100 times to acquire the degree of plasticity.
Specification
Specifications are subject to change without notice. | |
Model | No.105 WILLIAMS PLASTOMETER |
Specimen | Cylindrical shape, Volume 2 ± 0.02 cm3 (φ16 mm, H10 mm) |
Parallel Plate | Upper: φ148 mm, T11.7 mm Lower: φ148 mm, T13 mm |
Test Load | Initial 24.5 N (2.5 kgf) to Max. 49 ± 0.05 N (5 kgf) (Standard 49 ± 0.05 N) |
Dial Gauge | Scale 1/100 mm, Stroke Max. 20 mm |
Software | ― |
Accessories | Dial Gauge, Weight (4.9 N: 1 pc, 9.8 N: 2 pcs), Hexagon wrench, Set Up Disk (105-AUTO), Power Plug Adaptor (105-AUTO) |
Option | ― |
Power Source | ― |
Dimensions/Weight (Approx.) | W175 × D150 × H330 mm, 7.2 kg *With Dial Gauge Attached. |
No105-AUTO WILLIAMS PLASTOMETER (AUTOMATIC)
JIS K6249, ASTM D926, ISO 7323
- The No.105-AUTO is the automated version of the No.105 WILLIAMS PLASTOMETER.
- The tester can show the time series graph of the thickness on the computer screen.
Specification
Specifications are subject to change without notice. | |
Model | No.105-AUTO WILLIAMS PLASTOMETER (AUTOMATIC) |
Specimen | Cylindrical shape, Volume 2 ± 0.02 cm3 (φ16 mm, H10 mm) |
Parallel Plate | Upper: φ148 mm, T11.7 mm Lower: φ148 mm, T13 mm |
Test Load | Initial 24.5 N (2.5 kgf) to Max. 49 ± 0.05 N (5 kgf) (Standard 49 ± 0.05 N) |
Dial Gauge | Scale 1/100 mm, Stroke Max. 20 mm, Digital Display Ver. |
Software | Windows Compatible |
Accessories | Dial Gauge, Weight (4.9 N: 1 pc, 9.8 N: 2 pcs), Hexagon wrench, Set Up Disk (105-AUTO), Power Plug Adaptor (105-AUTO) |
Option | Heating Plate Type, Safety Cover |
Power Source | AC 100 V, 1-Phase, 5 A, 50/60 Hz |
Dimensions/Weight (Approx.) | W365 × D250 × H506 mm, 24 kg |
No.171 COMPRESSION SET TESTER
JIS A5756, K6262, ASTM D395, ISO 815
- This tester measures the compression set of vulcanized rubber and thermo-plastic rubber at room temperature, low temperature, and high temperature to acquire the settling of the test specimen.
- The compression ratio can be set by changing the spacer.
Specification
Specifications are subject to change without notice. | ||
Test Method | Large Specimen | Small Specimen |
Test Method | φ29.0 ± 0.5 mm T12.5 ± 0.5 mm |
φ13.0 ± 0.5 mm T6.3 ± 0.3 mm |
Spacer | 12 pcs, T9.3 to 9.4 mm (25 % Compression) |
12 pcs, T4.7 to 4.8 mm (25 % Compression) |
Dimensions/ Weight (Approx.) | W290 × D150 × H145 (20 × 3 Stages) mm, 20 kg | W290 × D150 × H145 (20 × 3 Stages) mm, 20 kg |
No.184-A MCBURNEY INDENTATION TESTER
JIS A1454, A5705
- This tester is to test the indentation of floor material.
- Adjusting the dial gauge to 0 within 5 seconds after setting an initial load of 9 N, the operator is then to add 133 N of load to the test specimen and read the indentation depth when 1 minute has past.
Specification
Specifications are subject to change without notice. | |
Weight Load | Initial 9 N, Total 133 ± 1N |
Indenter | Hemispherical shape, φ6.35 ± 0.01 mm |
Dial Gauge | Scale 1/100 mm, Stroke Max. 10 mm |
Dimensions/ Weight (Approx.) | W180 × D180 × H360 mm, 20 kg |
No.184-B RESIDUAL INDENTATION TESTER
JIS A1454, A5705
- This tester is to test the residual indentation of floor material.
- The operator is to apply 356 N of load to the test specimen for 10 minutes (if the test specimen is foamed material 222 N of load for 5 minutes).
- After the testing time has past, remove the load and read the indentation depth of the test specimen when 60 minutes has passed after the load has been removed.
Specification
Specifications are subject to change without notice. | |
Weight Load | 356 ± 1 N, 222 ± 1N |
Indenter | Standard: Flat shape, φ4.5 mm Famed Material: Hemispherical shape, φ19 mm |
Dial Gauge | Scale 1/100 mm, Stroke Max. 10 mm |
Option | Automatic Loading Device, Timer |
Dimensions/ Weight (Approx.) | W370 × D400 × H820 mm, 50 kg |
Inquiry Form