{"id":8439,"date":"2025-08-06T11:03:17","date_gmt":"2025-08-06T02:03:17","guid":{"rendered":"https:\/\/yasudaseiki.com\/en-test\/?p=8439"},"modified":"2025-08-07T08:38:59","modified_gmt":"2025-08-06T23:38:59","slug":"120-series","status":"publish","type":"post","link":"https:\/\/yasudaseiki.com\/en-test\/product\/120-series\/","title":{"rendered":"120 Series\uff5cMelt-Flow Rate (MFR, MFI, MVR, Flow Properties) Testers"},"content":{"rendered":"\n<section id=\"series-mv\" class=\"series-mv series-page\">\n    <div class=\"products-mv-item sp-hidden\">\n        <img decoding=\"async\" src=\"https:\/\/yasudaseiki.com\/en-test\/wp-content\/uploads\/2025\/08\/banner_120series_E.png\" alt=\"120series\">\n    <\/div>\n    <div class=\"products-mv-item pc-hidden\">\n        <img decoding=\"async\" src=\"https:\/\/yasudaseiki.com\/en-test\/wp-content\/uploads\/2025\/08\/banner_120series_EN_sp.png\" alt=\"120series\">\n    <\/div>\n<\/section>\n<section id=\"products-menu\" class=\"products-menu\">\n    <ul class=\"products-menu-inner\">\n        <li class=\"products-menu-inner-overview products-tab is-active\"><a href=\"#overview\">Overview<\/a><\/li>\n        <li class=\"products-menu-inner-comparison products-tab\"><a href=\"#comparison\">Comparison<\/a><\/li>\n    <\/ul>\n<\/section>\n<section id=\"overview\">\n    <div class=\"series-overview-item series-section-inner\">\n        <h2 class=\"products-h2\">Series Overview<\/h2>\n        <p>The most common method for evaluating the fluidity of thermoplastic resin is measuring the melt mass-flow rate (MFR) or melt volume-flow rate (MVR).<br>The 120 Series is a melt flow testing machine (Melt Indexer, Melt Flow Indexer, MI), specifically designed to measure MFR and MVR. With a lineup of manual, automatic, and full automatic models, we provide optimal solutions to meet diverse customer needs. All models are designed and manufactured in accordance with industry standards such as JIS, ISO, and ASTM.<br><br>The Melt Flow Index Tester is equipped with data management features, and designed with a focus on usability and safety. Notably, the high-end model [120-LABOT] is widely appreciated for its compact design relative to its functionality, low running costs, and minimal errors, making it a popular choice among customers. With extensive deliveries to large-scale petrochemical manufacturers, the 120 Series is a powerful tool at the frontlines of quality assurance and research and development.<\/p>\n        <p class=\"inner-contents\"><a href=\"https:\/\/yasudaseiki.com\/en-test\/what-is-mfr-and-mvr\/\">Learn more about MFR and MVR here<\/a><\/p>\n    <\/div>\n    <div class=\"series-overview-item series-section-inner\">\n        <h2 class=\"products-h2\">Reference Standards<\/h2>\n        <ul class=\"products-standard-list\">\n            <li>JIS K 6719-1\/2, K 6921-2, K 6922-2, K 6923-1, K 6924-1, K 6926-2, K 7210-1<\/li>\n            <li>ISO 1133-1<\/li>\n            <li>ASTM D1238<\/li>\n        <\/ul>\n    <\/div>\n<\/section>\n<section id=\"comparison\">\n    <div class=\"series-section-inner\">\n        <h2 class=\"products-h2\">Function Comparison<\/h2>\n        <div class=\"js-scrollable scroll-hint table-area\">\n            <span class=\"table-before-caption\">*Indicates optional fetures<\/span>\n            <table class=\"series-comparison-table series-comparison-3products\">\n                <thead>\n                    <tr>\n                        <th>Model<\/th>\n                        <th>120-LABOT (Full Automatic)<\/th>\n                        <th>120-SAS (Automatic)<\/th>\n                        <th>120-FWP (Manual)<\/th>\n                    <\/tr>\n                <\/thead>\n                <tbody>\n                    <tr>\n                        <td>Product Image<\/td>\n                        <td><img decoding=\"async\" src=\"https:\/\/yasudaseiki.com\/en-test\/wp-content\/uploads\/2025\/08\/120-LABOT_MFR_2508-03.png\" alt=\"120 LABOT\"><\/td>\n                        <td><img decoding=\"async\" src=\"https:\/\/yasudaseiki.com\/en-test\/wp-content\/uploads\/2024\/12\/120-SAS.png\" alt=\"120 SAS\"><\/td>\n                        <td><img decoding=\"async\" src=\"https:\/\/yasudaseiki.com\/en-test\/wp-content\/uploads\/2024\/12\/120-FWP.jpg\" alt=\"120 FWP\"><\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Continuous Testing<\/td>\n                        <td>1 to 50 cycles<\/td>\n                        <td>1 to 3 cycles<\/td>\n                        <td>&#8211;<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Sample Insertion<\/td>\n                        <td>Automatic<\/td>\n                        <td>Automatic<\/td>\n                        <td>Manual<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Measurement &#038; Data Processing<\/td>\n                        <td>Automatic*<\/td>\n                        <td>Automatic*<\/td>\n                        <td>Semi-automatic (Weight measurement is manual)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>A Method Cutting<\/td>\n                        <td>Automatic*<\/td>\n                        <td>Automatic*<\/td>\n                        <td>Automatic*<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Load Processing<\/td>\n                        <td>Loading\/Removal Automatic<\/td>\n                        <td>Loading\/Removal Automatic<\/td>\n                        <td>Loading Automatic\/Removal Automatic*<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Load Replacement<\/td>\n                        <td>Automatic*<\/td>\n                        <td>Automatic*<\/td>\n                        <td>Manual<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Cylinder Cleaning &#038; Die Cleaning<\/td>\n                        <td>Automatic<\/td>\n                        <td>Automatic<span class=\"products-table-caption\">(Gauze is pre-applied to cleaning rod by hand)<\/span><\/td>\n                        <td>Manual<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Piston &#038; Die Cleaning Rod Cleaning<\/td>\n                        <td>Automatic<\/td>\n                        <td>Automatic*<\/td>\n                        <td>Manual<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Key Points<\/td>\n                        <td>\n                            <ul>\n                                <li>Eliminates human error<\/li>\n                                <li>Improves safety<\/li>\n                                <li>Reduces labor costs<\/li>\n                                <li>Allows up to 50 continuous tests<\/li>\n                                <li>Increases operational efficiency by allowing other tasks to be performed during testing<\/li>\n                            <\/ul>\n                        <\/td>\n                        <td>\n                            <ul>\n                                <li>Eliminates human error<\/li>\n                                <li>Improves safety<\/li>\n                                <li>Reduces the workload for load replacement and cleaning<\/li>\n                                <li>The 3-sample capacity model (option) allows for 3 consecutive tests in a single cycle, further enhancing efficiency<\/li>\n                            <\/ul>\n                        <\/td>\n                        <td>\n                            <ul>\n                                <li>Low-cost option<\/li>\n                                <li>Suitable for applications with low test frequency or for R&#038;D purposes<\/li>\n                                <li>For frequent testing at different temperatures, multiple units can be dedicated to specific temperature ranges<\/li>\n                            <\/ul>\n                        <\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Product Page<\/td>\n                        <td class=\"products-table-btn\"><a href=\"https:\/\/yasudaseiki.com\/en-test\/product\/no120-labot\/\">View Details<\/a><\/td>\n                        <td class=\"products-table-btn\"><a href=\"https:\/\/yasudaseiki.com\/en-test\/product\/no120-sas\/\">View Details<\/a><\/td>\n                        <td class=\"products-table-btn\"><a href=\"https:\/\/yasudaseiki.com\/en-test\/product\/no120-fwp\/\">View Details<\/a><\/td>\n                    <\/tr>\n                <\/tbody>\n            <\/table>\n        <\/div>\n    <\/div>\n<\/section>\n<section class=\"products-contact\">\n    <div class=\"product-contact-area\">\n        <p class=\"product-contact-area-tittle\">Contact Us<\/p>\n        <p class=\"product-contact-area-text\">For over 70 years, Yasuda Seiki\u2019s testing machines have supported quality control and research &#038; development across various industries, meeting the diverse needs of our clients.<\/p>\n        <div class=\"product-contact-area-btn\">\n            <a href=\"https:\/\/yasudaseiki.com\/en-test\/contact\/\">Request a Quote \/ Contact Us<\/a>\n        <\/div>\n    <\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>Overview Comparison Series Overview The most common method for evaluating the fluidity of thermoplastic resin is measuring the melt mass-flow rate (MFR) or melt volume-flow rate (MVR).The 120 Series is a melt flow testing machine (Melt Indexer, Melt Flow Indexer, MI), specifically designed to measure MFR and MVR. With a lineup of manual, automatic, and [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":8440,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[30,28],"tags":[],"class_list":["post-8439","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-plastic_rubber","category-product"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/yasudaseiki.com\/en-test\/wp-json\/wp\/v2\/posts\/8439","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yasudaseiki.com\/en-test\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yasudaseiki.com\/en-test\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yasudaseiki.com\/en-test\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/yasudaseiki.com\/en-test\/wp-json\/wp\/v2\/comments?post=8439"}],"version-history":[{"count":1,"href":"https:\/\/yasudaseiki.com\/en-test\/wp-json\/wp\/v2\/posts\/8439\/revisions"}],"predecessor-version":[{"id":8451,"href":"https:\/\/yasudaseiki.com\/en-test\/wp-json\/wp\/v2\/posts\/8439\/revisions\/8451"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yasudaseiki.com\/en-test\/wp-json\/wp\/v2\/media\/8440"}],"wp:attachment":[{"href":"https:\/\/yasudaseiki.com\/en-test\/wp-json\/wp\/v2\/media?parent=8439"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yasudaseiki.com\/en-test\/wp-json\/wp\/v2\/categories?post=8439"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yasudaseiki.com\/en-test\/wp-json\/wp\/v2\/tags?post=8439"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}